In brief
The short answer
NEN 1010 divides the bathroom into four areas: zone 0 (inside the bath or shower tray itself), zone 1 (directly above it up to 225 cm high), zone 2 (60 cm alongside) and the area beyond. The closer to the water, the stricter the requirements. In zone 0 only low voltage is allowed (SELV, usually 12 volts) with a protection rating of IPX7. In zones 1 and 2 a minimum of IPX4 applies and ordinary sockets are not permitted. Beyond the zones, normal sockets are allowed, provided the whole bathroom is protected by a 30 milliamp RCD.
- NEN 1010 divides the bathroom into zone 0, 1, 2 and the area beyond.
- The IP rating tells you how well a fitting is protected against dust and water.
- The closer to the water, the higher the requirement: from IPX4 to IPX7.
- Ordinary sockets are not allowed in the wet zones, only beyond them.
- The whole bathroom should be protected by a 30 mA RCD.
Why the bathroom is divided into zones
A bathroom is a wet room, and that makes it special from an electrical point of view. Moisture, splashing water and sometimes immersion mean that current finds a path to your body far more easily than in a dry room. Stand with wet feet on a wet floor and your resistance is low, so a fault that would be harmless elsewhere can end badly here. For that reason NEN 1010, the standard for safe electrics in and around the home, sets extra requirements for everything you connect in a bathroom.
Those requirements are not the same everywhere in the room. Just above the bath the risk is greater than by the door on the far side. That is why the standard works with zones: imaginary areas around the bath and shower, each with its own degree of strictness. The closer to the water, the higher the requirements for the protection of a fitting, and the lower the voltage that may safely run there.
The idea behind it is simple: in the place where water and person are closest, as little energy as possible should be available and every device must be fully protected against water. Moving outwards, away from the bath, a little more is gradually allowed. That way you keep the bathroom usable without losing sight of safety.
The four zones, from bath to door
Zone 0 is the area inside the bath or shower tray itself: where the water sits. This is the strictest zone. Only devices expressly made for this spot are allowed here; they must be waterproof to immersion (IPX7) and run on safe low voltage, usually 12 volts SELV via an isolating transformer outside the bathroom.
Zone 1 is the space directly above zone 0, up to a height of 225 cm above the floor. Think of the wall above the bath or shower, where a recessed spotlight or a suitable water heater can be fitted, for example. Here a minimum of IPX4 applies, so protection against splashing water from all directions. Ordinary sockets are not allowed here.
Zone 2 runs 60 cm horizontally on from the edge of zone 1, also up to 225 cm high. This is the area directly beside the bath or shower, where a wall fitting by the mirror might sit, for example. Here too IPX4 is the minimum. Sockets are not permitted in this zone, with the exception of a shaver socket with a built-in isolating transformer.
Everything beyond these zones counts as normal, provided it stays reasonably clear of splashing water. There, ordinary sockets and switches are allowed, along with fittings without a special IP requirement. However, for the whole bathroom the circuit must be protected by a 30 milliamp RCD, whichever zone you are in.
What the IP rating means
IP stands for Ingress Protection, the degree to which a device is protected against the ingress of dust and water. After the letters come two digits: the first is about solid particles and dust, the second about water. For bathroom fittings it is mainly that second digit that matters, which is why you often see a notation like IPX4, where the X means the dust digit is not specified here.
IPX4 means protection against splashing water from all directions: a fitting that can handle this is unaffected if water splashes against it. That is the minimum requirement in zones 1 and 2. IPX5 goes a step further and withstands water jets, handy if you clean the shower or room with a jet. IPX7, finally, means a device withstands temporary immersion, and that is exactly why that requirement applies to zone 0, inside the bath.
A higher second digit is therefore stricter, and the zone determines which minimum you need. If you buy a spotlight or wall light for the bathroom, always check the IP rating on the packaging and compare it with the zone where it will hang. An ordinary lamp from the living room, without an IP marking, does not belong within the wet zones.
Why you have this done by a certified electrician
On paper the zones look manageable, but in practice the safety is in the details. The right IP rating per zone, a 30 milliamp RCD that actually switches off in time, good earthing and the question of whether your existing circuit safely feeds the bathroom: together that makes the difference. A fault is invisible from the outside, until it goes wrong in the worst possible place.
Work on the fixed installation in a wet room therefore belongs with a certified professional who works to NEN 1010. That is not only safer, it is also important for your insurance: if something goes wrong with electrics that were not installed to the standard, cover can come into question. A certified electrician tests the installation afterwards and hands it over demonstrably safe.
Not sure whether your bathroom is still up to standard, for instance in an older home or after a past renovation? Have it checked at your leisure. We assess the zones, the IP ratings and the protection, and tell you honestly what is needed and what is simply fine.
At a glance
The bathroom zones at a glance
Roughly, this is how the zones in the bathroom work. Handy to know before you have a light or socket fitted.
| Zone | Description | What is allowed there | IP requirement (minimum) |
|---|---|---|---|
| Zone 0 | Inside the bath or shower tray itself | Only low voltage (SELV, usually 12 V), specifically for this spot | IPX7 |
| Zone 1 | Directly above zone 0, up to 225 cm high | Suitable fittings and water heater, no ordinary sockets | IPX4 |
| Zone 2 | 60 cm horizontally beside zone 1, up to 225 cm high | Wall fittings, only a shaver socket as a socket | IPX4 |
| Beyond the zones | The rest of the bathroom, clear of splashing water | Ordinary sockets, switches and fittings | No special IP requirement |
For the whole bathroom, moreover: the circuit should be protected by a 30 mA RCD.
Read also
Read on and arrange it
Want to take the step or dig deeper? These pages set you on your way, from safe lighting to the standard behind it.
Why Brabant Elektra
Prefer to have a professional take a look?
Our certified electricians work across all of Noord-Brabant to NEN 1010, with a fixed price upfront and a 2-year work guarantee. Certified, insured and straightforwardly professional.

Frequently asked questions
Good to know
Service area
An electrician near you
From Eindhoven to Breda and from Den Bosch to Tilburg: our certified electricians come to you, with a fixed price upfront.
Service area
Across Noord-Brabant
From major cities to smaller towns, active in:
Safe electrics in the bathroom?
From lighting in the right zone to sockets and good RCD protection: we install your bathroom to NEN 1010 and hand it over demonstrably safe. Feel free to request a quote, so you know where you stand beforehand.