Brabant Elektra
Consumer unit & meter cabinet

RCD replacement

The RCD protects you from electric shock. If it is no longer working, trips frequently or is missing altogether, we replace or fit one safely to NEN 1010, with a fixed price upfront.

4,8· 312 reviews
Certified installer2-year guaranteeInsured

About this job

What does an RCD do, and why is it so important?

The RCD (earth leakage circuit breaker) is the most important safety device in your meter cabinet. It continuously monitors whether all the current going into a circuit also comes back out. If current leaks away, for example through a faulty appliance, a damaged cable or moisture in the bathroom, it switches off within milliseconds. That difference of 30 milliamps (30 mA) is precisely calibrated to protect you from electrocution: it is the difference between a fright and a life-threatening shock.

An ordinary fuse or circuit breaker protects the wiring from overload and short circuits, but not you from a shock. That is what only the RCD does. This is why NEN 1010, the standard for safe electrical installations in the home, requires at least two 30 mA RCDs in the consumer unit, so that your whole house does not all go off at once and protection is always maintained. If your RCD is not working properly or is missing, you are unprotected. That is not something to put off.

Warning signs

When should you replace or add an RCD?

Some signs point to wear or a fault; others indicate a consumer unit that no longer meets the standard. If you recognise any of them, have your RCD checked without delay.

  • It trips frequently

    An RCD that keeps tripping is usually warning of a real leakage current in an appliance or cable. The cause should be identified first, then the RCD replaced.

  • The test button does not respond

    The T button should make the RCD trip immediately. If it does not, the protection is no longer reliable and the RCD must be replaced.

  • An old consumer unit without an RCD

    An old-style fuse box or consumer unit without an RCD offers no protection against shock. We fit one, or replace the whole unit.

  • Burning smell or discolouration near the unit

    Can you smell burning or see brown marks around the RCD? That is urgent. Call us and we will come and take a look straight away.

  • After a shock

    Did you get a shock from an appliance or tap? Have your installation checked. The RCD is there specifically to protect you from exactly that kind of shock.

  • Extension or new heavy appliances

    An EV charger, heat pump or extra circuit often needs its own RCD protection. When extending, we check straight away whether your consumer unit still meets the standard.

How we work

How we approach it

When an RCD is tripping, we find the cause first, then replace it. Safe and with a fixed price upfront.

  1. 1

    Check and find the cause

    We test the RCD and, where it is tripping, identify the cause first. Simply replacing it will not fix a genuine leakage current.

  2. 2

    Fixed price upfront

    You know what the issue is and receive a clear price before we start. Whether we are replacing, adding or tracing the fault first: you choose with full knowledge, no surprises.

  3. 3

    Safe replacement or fitting

    We de-energise the installation and fit a new 30 mA RCD from a reputable brand. Neatly connected and the circuits clearly labelled again.

  4. 4

    Testing and handover

    We test the installation and check the RCD's trip time, proving the protection works. We then hand over neatly, with a 2-year work guarantee.

DIY?

Can you replace an RCD yourself?

Pressing the test button is something you should absolutely do yourself, preferably a few times a year. It is how you check whether the protection is still working. Replacing or connecting the RCD itself is work inside the consumer unit and must be carried out by a certified electrician, in accordance with NEN 1010.

What you can do yourself

  • Press the test button (T) a few times a year as a check
  • Switch the RCD back on normally after testing
  • Call us to have a look if you are unsure or there is a fault

What to leave to a certified electrician

  • Replace or connect the RCD yourself
  • Work inside a consumer unit that is live
  • Tape over or bypass an RCD that keeps tripping

Good to know

The technical side, in plain English

A few questions that come up regularly around RCDs. We explain them calmly.

RCD or combined circuit breaker (RCD+MCB)?

An RCD protects several circuits at once against leakage current but has no overload protection of its own. That is handled by the individual circuit breakers, the modern replacements for fuses. If the RCD trips, all circuits behind it go off at once, leaving, for example, a whole floor without power.

A combined circuit breaker (RCD+MCB) combines both in one module, per circuit: protection against shock and protection of the wiring together. If something goes wrong in the bathroom, only that circuit goes off and the rest of your home stays on. They cost a little more per unit, but offer more convenience and certainty. We give honest advice on what makes sense in your consumer unit.

Why specifically 30 mA?

The 30 mA refers to the leakage current difference at which the RCD trips: 30 milliamps. This is deliberately low, because a current through your body can become dangerous at that level. By switching off within milliseconds, the RCD keeps the duration and strength of any shock below the threshold that your heart and muscles can withstand.

This is called personal protection: the RCD is not there to protect your appliances, but to protect you and the people in your home. That is why every circuit that people can come into contact with must be protected by a 30 mA RCD. An older 300 mA RCD only protects against fire, not against a shock, and is therefore not adequate as personal protection.

Type A or type B: which do you need?

For standard household circuits, a type A RCD is the norm. It detects both normal AC leakage and the pulsating DC leakage that modern electronics can cause. For virtually everything in the home, type A is the right choice.

Type B is a heavier version that also detects pure DC leakage and is considerably more expensive. Type B was often mentioned for EV chargers, but many modern chargers already have built-in DC detection, which means an ordinary type A RCD is usually sufficient. We check the specification of your charger and advise on what is genuinely needed, so you do not pay unnecessarily for type B.

Price

What does RCD replacement cost?

The price depends on your situation: replacement only, adding an RCD to the consumer unit, or tracing a fault first. That is why we look first, then give you a fixed price upfront. Below is an indication per scenario.

Common extras:

  • Type A for standard household circuits, usually sufficient
  • Trace the cause first when an RCD keeps tripping
  • Extra RCD when your consumer unit has only one

Price guide

Fixed price upfront
RCD replacement€ 90 to € 200
Adding an RCD to the consumer unit€ 120 to € 250
RCD tripping: fault tracingfrom € 89
Surcharge for combined circuit breaker (RCD+MCB) per circuit+ € 30 to € 60

Indicative prices incl. VAT. You will always receive a tailored quote.

Why Brabant Elektra

Certified, insured and guaranteed

All our engineers are qualified and work to the NEN 1010 standard. We give a 2-year guarantee on all our work. Reliable work you can count on.

4,8· 312 reviews
Certified installer2-year guaranteeInsured
The Brabant Elektra team: eight qualified engineers in company clothing

Frequently asked questions

Good to know

An RCD that keeps tripping is almost always warning of a real leakage current, usually in an appliance or cable. First unplug everything, switch the RCD back on and plug the appliances back in one by one. If it keeps tripping without finding the cause, call us. We trace the leakage current before replacing anything, because fitting a new RCD does not fix a genuine leak.
Indicatively € 90 to € 200 for replacing an RCD, and € 120 to € 250 for adding one to your consumer unit. If the fault needs tracing first because the RCD is tripping, that starts from € 89. You always get a fixed price upfront, so you know exactly where you stand.
No. You can and should press the test button to check whether the RCD works. But replacing or connecting the RCD is work inside the consumer unit and must be done by a certified electrician, in accordance with NEN 1010. That is not just safer; it also matters for your insurance.
An RCD protects several circuits at once against shock, but has no overload protection of its own: that is handled by the individual circuit breakers behind it. A combined circuit breaker (RCD+MCB) incorporates both in one module per circuit. If something goes wrong, only that one circuit trips instead of a whole block. Combined circuit breakers are somewhat more expensive, but offer more convenience. We advise on what makes sense in your consumer unit.
The test button should make the RCD trip immediately. If it does not, the protection is no longer reliable and you may be unprotected against shock. Have the RCD replaced. Test it preferably a few times a year so you know the protection is working.
The 30 mA is the sensitivity: when a leakage current of 30 milliamps is detected, the RCD trips within milliseconds. That value is deliberately low, because above it a current through your body becomes dangerous. A 30 mA RCD is therefore personal protection, designed to protect you against shock. NEN 1010 requires at least two of these RCDs in the consumer unit.
Often not. For ordinary household circuits, type A is the standard. Type B is a heavier and more expensive version that also detects pure DC leakage. Many modern EV chargers already have that DC detection built in, which means an ordinary type A RCD is usually sufficient. We check the specification of your charger and advise on what is genuinely needed, so you do not pay unnecessarily for type B.
As long as the unit remains in place it is not illegal, but it is not safe: without an RCD you are not protected against electric shock. In many cases we can still fit a 30 mA RCD. If the unit is very old or full, a new consumer unit is sometimes the better and safer choice. We assess what makes sense in your situation when we survey.

Service area

RCD replacement across Noord-Brabant

We replace and fit RCDs throughout Noord-Brabant, from Eindhoven to Breda and from Tilburg to Den Bosch, including all the towns and villages in between. A certified engineer near you, making your meter cabinet safe to NEN 1010, who can often come the same day when your RCD is tripping to track down the cause.

Brabant has many older properties, and that is exactly where you sometimes still find an old-style fuse box without an RCD, or one that is past its best. We know these units and understand how the Enexis network is wired in the region. We fit a 30 mA RCD, or advise you honestly whether a new consumer unit is the safer choice. Wherever you live in the region, we make sure you are protected against shock again.